When collecting data in USB memory
Connect the USB memory to the USB port on the XSCFU.
1.
Figure 8-2     Connecting the USB Memory
2.
Execute the snapshot command to collect XSCF log information.
The following example collects all the XSCF log information for a building block
configuration.
XSCF> snapshot -d usb0 -L F -r -a -v
Testing writability of USB device....SUCCESS
About to remove all files from device 'usb0'. Continue? [Y|N] : y
BB#00: start to execute snapshot
BB#01: start to execute snapshot
.
.
Collecting data into /media/usb_msd/<hostname>_<ipaddress>_<date>.zip
Data collection complete.
When collecting information on the SSH server
Execute the snapshot command to collect XSCF log information.
1.
Note that the content of the message may differ depending on the firmware
version.
XSCF> snapshot -t <a>root@ssh_server:/home/snapshot/ -L F -v -a
Downloading Public Key from 'ssh_server'...
Enter ssh password for user 'root' on host 'ssh_server':
Setting up ssh connection to <a>root@ssh_server...
Collecting data into root@ssh_server:/home/snapshot/M12-2S_192.168.1.100_
2016-09-12T06-53-39.zip
BB#00: start to execute snapshot
Chapter 8 Preparation for Maintenance