Table 5-7     Active/Cold Addition Procedure of Memory
Work
Order
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
160
Fujitsu SPARC M12-2/M12-2S Service Manual ・ January 2023
Task
Checking the operating condition of the
system
Checking the logical domain assignment
status of CPU resources mounted in the
SPARC M12-2S requiring maintenance
Checking the logical domain assignment
status of memory resources mounted in
the SPARC M12-2S requiring maintenance
Releasing the logical domain assignment
of PCIe cards mounted in the SPARC
M12-2S requiring maintenance
Releasing the SPARC M12-2S requiring
maintenance from the physical partition
Switching the mode switch on the OPNL
to Service
Releasing the SPARC M12-2S requiring
maintenance from the building block
configuration, and removing the power
cords
Removing the CMU from the SPARC
M12-2S
Installing memory in the CMU and
installing this unit in the SPARC M12-2S
Installing the power cords on the SPARC
M12-2S requiring maintenance, and
incorporating it into the building block
configuration
Diagnosing the SPARC M12-2S requiring
maintenance (*1)
Diagnosing the XBU and crossbar cable
of the SPARC M12-2S requiring
maintenance
Confirming that there is no problem with
the added memory
Incorporating the SPARC M12-2S into the
physical partition
Switching the mode switch on the OPNL
to Locked
Reference
"9.2.1 Checking the Operation Status of
Physical Partitions and Logical
"3.2.4 Checking the Assignment Status
of Resources" in the Fujitsu SPARC M12
and Fujitsu M10/SPARC M10 Domain
Configuration Guide
"3.2.4 Checking the Assignment Status
of Resources" in the Fujitsu SPARC M12
and Fujitsu M10/SPARC M10 Domain
Configuration Guide
"9.3 Releasing I/O Resources From a
Logical
Domain"
"9.4.3 Dynamically Releasing the
SPARC M12-2S From the Physical
Partition"
"2.3.2 OPNL Control
Function"
"9.6.1 Releasing the SPARC M12-2S
From the Building Block
Configuration"
"9.8.2 Removing the Power
"17.4 Removing the CMU or
"17.5 Installing the CMU and
"10.1.1 Installing a Power
"10.4.1 Incorporating the SPARC
M12-2S Into a Building Block
Configuration"
"10.5.1 Diagnosing the SPARC M12
Hardware"
"10.5.2 Diagnosing the XBU and
Crossbar
Cable"
"10.5.3 Checking the FRU Status After
Maintenance"
"10.6.1 Incorporating the SPARC
M12-2S Into the Physical Partition Using
PPAR
DR"
"2.3.2 OPNL Control
Function"
Domains"
Cords"
Memory"
Memory"
Cord"

Advertisement

Table of Contents
loading

This manual is also suitable for:

Oracle sparc m12-2s

Table of Contents