XSCF> showlogs error
Check the hardware configuration.
4.
Enter the showhardconf command to check that the replacement FRU has been
incorporated into the system. If there is an error, an asterisk (*) appears at the
beginning of the line on which the corresponding FRU name is shown.
If the XSCFU has been replaced, confirm that the combination of the XSCFU and
CMUL types is correct. For details, see
Information."
XSCF> showhardconf
SPARC M12-2S;
+ Serial:PZ51649002; Operator_Panel_Switch:Service;
+ System_Power:On; System_Phase:Cabinet Power On;
Partition#0 PPAR_Status:Running;
BB#00 Status:Normal; Role:Master; Ver:3015h; Serial:PZ51649002;
+ FRU-Part-Number:CA20369-B17X 005AC/7341758
+ Power_Supply_System: ;
+ Memory_Size:256 GB;
CMUL Status:Normal; Ver:2101h; Serial:PP164804GG
+ FRU-Part-Number:CA07855-D301 A5
+ Memory_Size:128 GB; Type: C ;
CPU#0 Status:Normal; Ver:4242h; Serial:00070051;
+ Freq:4.250 GHz; Type:0x30;
+ Core:12; Strand:8;
MEM#00A Status:Normal;
+ Code:ce8002M393A2K40BB1-CRC
+ Type:83; Size:16 GB;
MEM#01A Status:Normal;
+ Code:ce8002M393A2K40BB1-CRC
+ Type:83; Size:16 GB;
MEM#02A Status:Normal;
+ Code:ce8002M393A2K40BB1-CRC
+ Type:83; Size:16 GB;
MEM#03A Status:Normal;
+ Code:ce8002M393A2K40BB1-CRC
+ Type:83; Size:16 GB;
MEM#04A Status:Normal;
+ Code:ce8002M393A2K40BB1-CRC
+ Type:83; Size:16 GB;
MEM#05A Status:Normal;
+ Code:ce8002M393A2K40BB1-CRC
+ Type:83; Size:16 GB;
MEM#06A Status:Normal;
+ Code:ce8002M393A2K40BB1-CRC
+ Type:83; Size:16 GB;
MEM#07A Status:Normal;
+ Code:ce8002M393A2K40BB1-CRC
+ Type:83; Size:16 GB;
CMUU Status:Normal; Ver:2101h; Serial:PP164804GN
+ FRU-Part-Number:CA07855-D451 A4
+ Memory_Size:128 GB; Type: C ;
352
Fujitsu SPARC M12-2/M12-2S Service Manual ・ January 2023
Table 8-2
in
"8.1.6 Checking FRU
;
/7341541
00-31C04E6E;
00-31C04ED1;
00-31C0510D;
00-31C04F51;
00-31C04E6F;
00-31C04F50;
00-31C04EFB;
00-31C051AE;
;
/7341568
;
;
;