Goodrive350 series high-performance multifunction VFD

5.5.16 Run at wobbling frequency

Wobbling frequency is mainly applied in cases where transverse movement and winding functions are
needed like textile and chemical fiber industries. The typical working process is shown as below.
Keypad
P00.10
Frequency set by
AI1
keypad
AI2
AI3
HDIA
Simple PLC
Multi-step speed
PID
MODBUS
PROFIBUS
Ethernet
HDIB
AB pulse string
EtherCat/Profinet
PLC programmable
card
Function
code
P00.03
Max. output frequency
A frequency command
P00.06
P00.11
Acceleration time 1
P00.12
Deceleration time 1
P00.06
(A frequency command
Amplitude of wobbling
selection)
frequency
0
P08.05
1
2
3
4
*
5
*
6
7
Terminal function 26
wobbling frequency
8
9
10
11
12
13
14
Name
selection
Maintain current
frequency
Valid
Set frequency
Invalid
Wobbling frequency reset
pause
Description
P00.03–400.00Hz
0: Keypad
1: AI1
2: AI2
3: AI3
4: High speed pulse HDIA
5: Simple PLC program
6: Multi-step speed running
7: PID control
8: Modbus communication
9: PROFIBUS/CANopen/DeviceNet
communication
10: Ethernet communication
11: High speed pulse HDIB
12: Pulse string AB
13: EtherCAT/PROFINET
communication
14: PLC card
0.0–3600.0s
0.0–3600.0s
-115-
Basic operation instructions
Valid
Invalid
Terminal function 27
P00.11 acceleration time 1
P00.12 deceleration time 1
Wobbling
frequency
output
Default
value
50.00Hz
0
Depends
on model
Depends
on model