Goodrive350 series high-performance multifunction VFD
Function
code
Function parameter
P00.18
P02.00
Type of motor 1
Rated power of
P02.01
asynchronous motor 1
Rated frequency of
P02.02
asynchronous motor 1
Rated speed of
P02.03
asynchronous motor 1
Rated voltage of
P02.04
asynchronous motor 1
Rated current of
P02.05
asynchronous motor 1
Rated power of
P02.15
synchronous motor 1
Rated frequency of
P02.16
synchronous motor 1
Number of pole pairs of
P02.17
synchronous motor 1
P02.18
Rated voltage of
Name
when current motor is motor 1, only P02.06,
P02.07 and P02.08 will be autotuned; when
current motor is motor 2, only P12.06,
P12.07 and P12.08 will be autotuned.
4: Rotary autotuning 2, which is similar to
rotary autotuning 1 but is only applicable to
asynchronous motors.
5: Rotary autotuning 3 (partial autotuning),
which is only applicable to asynchronous
motors.
0: No operation
1: Restore to default value
2: Clear fault history
Note: After the selected function
operations are done, this function code
restoration
will be restored to 0 automatically.
Restoration to default value will clear the
user password, this function should be
used with caution.
0: Asynchronous motor
1: Synchronous motor
0.1–3000.0kW
0.01Hz–P00.03 (Max. output frequency)
1–60000rpm
0–1200V
0.8–6000.0A
0.1–3000.0kW
0.01Hz–P00.03 (Max. output frequency)
1–50
0–1200V
Description
-52-
Basic operation instructions
Default
value
0
0
Depends
on model
50.00Hz
Depends
on model
Depends
on model
Depends
on model
Depends
on model
50.00Hz
2
Depends

Advertisement