Motor Parameter Autotuning; Parameter Backup - INVT Goodrive350 Series Operation Manual

High-performance multifunction vfd
Hide thumbs Also See for Goodrive350 Series:
Table of Contents

Advertisement

Goodrive350 series high-performance multifunction VFD
key to enter state monitoring interface. After entering state monitoring interface, the current parameter
value will be displayed in real time, this value is the actually detected value which cannot be modified.
In state monitoring interface, press
16:02:35
Forward
P17.00:Set frequency
P17.01: Output frequency
P17.02: Ramps reference frequency
P17.03: Output voltage
P17.04: Output current
P17.05: Motor speed
Return

5.4.8 Motor parameter autotuning

In "Motor parameter autotuning" menu, press
parameter autotuning selection interface, however, before entering motor parameter autotuning
interface, you must set the motor nameplate parameters correctly. After entering the interface, select
motor autotuning type to carry out motor parameter autotuning. In motor parameter autotuning
interface, press
16:02:35
Forward
Local
Ready
Common parameter setup
Parameter setup
State monitoring/fault record
Motor parameter autotuning
Parameter backup/restore to default value
System setting
Return
Homepage
After selecting motor autotuning type, enter motor parameter autotuning interface, and press RUN
key to start motor parameter autotuning. After autotuning is done, a prompt will pop out indicating
autotuning is succeeded, and then it will return to the main interface of stop. During autotuning, you
can press STOP/RST key to terminate autotuning; if any fault occur during autotuning, the keypad will
pop out a fault interface.
16:02:35
Autotuning step:1
In parameter autotuning
Return

5.4.9 Parameter backup

In "parameter backup" menu, press
backup setting interface and function parameter restoration setup interface to upload/download VFD
parameters, or restore VFD parameters to default value. The keypad has three different storage
Local
Ready
01: GD350
Add
Select
Figure 5.17 State monitoring interface
key or
key to return to the previous menu.
16:02:35
Ensure motor nameplate parameters are set
correctly!
Return
Select
Figure 5.18 Parameter autotuning operation diagram
Forward
Local
Run
01: GD350
Homepage
Stop
Figure 5.19 Parameter autotuning finished
key or
key to return to the previous menu.
16:02:35
Setting frequency
Max. value: 630.00
Min. value: 0.0
Default value: 0.0
Return
key,
key or
Forward
Local
Ready
01: GD350
Add
Confirm
16:02:35
Forward
Autotuning step:3
In parameter autotuning
Return
key,
key or
-45-
Basic operation instructions
Forward
Local
Ready
01: GD350
Hz
50.00
Homepage
Confirm
key to enter motor
16:02:35
Forward
Complete parameter rotary autotuning
Complete parameter static autotuning
Partial parameter static autotuning
Return
Local
Run
01: GD350
Homepage
Stop
key to enter function parameter
Local
Ready
01: GD350
Homepage
Confirm