Goodrive350 series high-performance multifunction VFD
Note: If fault occurred, rule out the fault cause according to "fault tracking".
The running command channel can be set by terminal commands besides P00.01 and P00.02.
Current running
command channel
P00.01
Keypad
Terminal
Communication
Note: "/" means this multi-function terminal is invalid under current reference channel.
Related parameter list:
Function
code
P00.00
Speed control mode
Running command
P00.01
Communication running
P00.02
command channel
Motor parameter
P00.15
Multi-function
terminal function (36)
Command switches
to keypad
/
Keypad
Keypad
Name
0: SVC 0
1: SVC 1
2: SVPWM
3: VC
Note: If 0, 1 or 3 is selected, it is required
to carry out motor parameter autotuning
first.
0: Keypad
1: Terminal
channel
2: Communication
0: Modbus
1: PROFIBUS/CANopen/DeviceNet
2: Ethernet
3: EtherCAT/PROFINET
4: PLC programmable card
5: Bluetooth card
0: No operation
1: Rotary autotuning 1; carry out
comprehensive motor parameter autotuning;
rotary autotuning is used in cases where high
control precision is required;
autotuning
2: Static autotuning 1 (comprehensive
autotuning); static autotuning 1 is used in
cases where the motor cannot be
disconnected from load;
3: Static autotuning 2 (partial autotuning) ;
Multi-function terminal
function (37)
Command switches to
terminal
Terminal
/
Terminal
Description
-51-
Basic operation instructions
Multi-function terminal
function (38)
Command switches to
communication
Communication
Communication
/
Default
value
2
0
0
0