MB90335 Series
Figure 4.2-1 Oscillation Stabilization Wait Times for the Evaluation/flash and MASK Products during
Evaluation/Flash Products
V
CC
CLK
CPU
operation
MASK Products
V
CC
CLK
CPU
operation
HCLK :
Note:
For ceramic or quartz oscillators, typically the oscillation stabilization wait time of several to some
tens of milliseconds is required until the oscillation is stabilized at the natural oscillation. after it
begins. For this reason, set the wait time value meeting the oscillator used.
For details, see "5.5 Oscillation Stabilization Wait Time"
■ Oscillation Stabilization Waiting Reset State
The reset operation in response to a reset which occurs during power on reset or in stop mode begins after
passing the oscillation stabilization wait time produced by the time-base timer expires. The reset operation
is performed after the external reset is released.
CM44-10137-6E
Power on Reset Time
17
2
2
/HCLK
Down-conversion
Oscillation Stabilizing
Stabilizing Wait Time
Wait Time
17
2
/HCLK
Oscillation Stabilizing Wait Time
Oscillation clock
FUJITSU MICROELECTRONICS LIMITED
4.2 Reset Factors and Oscillation Stabilization Wait Times
17
/HCLK
CHAPTER 4 RESET
115