r
DID and DIL trunks will not ring external page speakers. Only trunks defined as "normal" in
Program 22-02-01 will ring external page speakers.
• Paging keys can be assign on Programmable Function Keys and Direct Station Selection
r
(DSS) Consoles to simplify External Paging operation.
r
If a PGD(2)-U10 ADP circuit has a Door Box connected, you cannot use that circuit for
External Paging.
r
To have outside calls ring External Paging Zones at night, refer to the Night Service feature
and Program 31-05.
The PGD(2)-U10 ADP can only be connected to an ESIB(8)-U20 ETU. if the PGD(2)-U10
r
ADP is connected to an ESIE(8)-U20 ETU, the PGD(2)-U10 ADP will NOT be recognized.
When a ESIB(8)-U20 ETU has an ESIE(8)-U20 ETU installed [ESIB/E(16)], the
r
PGD(2)-U10 ADP will have both channels available for Paging, MOH, External Ringers and
Door Box according to strapping on ports 1-8. The corresponding port on the ESIE(8)-U20
ETU will not support a station or other hardware (it is used by the PGD(2)-U10 ADP for
channel 2).
When a ESIB(8)-U20 ETU is installed without an ESIE(8)-U20 ETU installed, a
r
PGD(2)-U10 ADP installed on ports 1~8 will be recognized, but only channel 1 on the
PGD(2)-U10 ADP is supported. Channel 2 is not available.
r
ESIB(8)-U10 ETUs and ESIE(8)-U10 ETUs do not support the PGD(2)-U10 ADP.
r
A maximum number of PGD(2)-U10 ADP is 56 and refer to the Hardware Manual for more
information which will describe how many of the 56 can be for paging, door box or Music on
Hold (MOH).
Default Setting
No External Paging defined.
System Availability
Terminals
All Stations
Required Component(s)
r
ESIB(8)-U20 ETU for PGD(2)-U10 ADP
r
ESIE(8)-U20 ETU for 2nd channel support