20-11-21
Class of Service Options (Hold/Transfer Service) - Restriction for Tandem Trunking on
Hang Up
Deny (1) an extension user's ability to set up a tandem call automatically when they hang up.
20-11-22
Class of Service Options (Hold/Transfer Service) - Unsupervised Conference Restriction
In an extensions's Class Of Service, Disable (0) or Enable (1) the extensions ability to initiate an
unsupervised conference.
20-13-08
Class of Service Options (Supplementary Service) - Conference
In an extension's Class of Service, enable (1) or disable (0) the extension's ability to initiate a
conference.
20-13-10
Class of Service Options (Supplementary Service) - Barge-In Mode
In an extension's Class of Service, set whether an extension should be able to Barge-In to a call
and talk (1) or just monitor the call (0).
24-02-07
System Options for Transfer - Trunk-to-Trunk Transfer Release Warning Tone
This timer will start when a trunk begins talking with another trunk (for example: trunk-to-trunk
transfer, outgoing from trunk, Tandem Trunking) (0~64800 seconds).
24-02-10
System Options for Transfer - Trunk to Trunk Transfer Disconnect Time
This timer will start after the Trunk to Trunk warning tone is heard.(0~64800 seconds).
25-07-07
System Timers for VRS/DISA -DISA/Tandem Trunking Conversation Warning Tone Time
Determine the length of time a DISA caller or a Tandem Trunking conversation can talk before
the Long Conversation tone is heard (0~64800 seconds).
25-07-08
System Timers for VRS/DISA - DISA/Tandem Trunking Long Conversation Disconnect
This timer determines how long the system will wait before disconnecting a call after the Long
Conversation tone is heard (0~-64800 seconds).
Tandem Trunking Method B - Tandem Trunking with Transfer Key
10-07-01
Conversation Record Circuits
The number of circuits assigned as Conversation Record circuits limits the number of available
Conference circuits. Make sure there are circuits available for the conference.
14-01-04
Basic Trunk Data Setup - Transmit Gain Level for Conference and Transfer Calls
Select the CODEC gain type used by the trunk when it is part of an Unsupervised Conference.
14-01-05
Basic Trunk Data Setup - Receive Gain Level for Conference and Transfer Calls
Select the CODEC gain type used by the trunk when it is part of an Unsupervised Conference.
14-01-13
Basic Trunk Data Setup - Loop Disconnect Supervision
For each trunk, enter 1 to enable loop supervision.
15-07-01
Programmable Function Keys
Assign a function key for Transfer (code 06).
Tandem Trunking (Unsupervised Conference)