34-08-01
Toll Restriction Data for E&M Tie Lines
Define the toll restriction data for E&M tie lines if required. This should be defined if toll
restriction is enabled in Program 21-05-13.
80-03-01
DTMF Tone Receiver Setup
80-04-01
Call Progress Tone Detector Setup
If required, modify the criteria for dial tone detection and call progress tone detection for tie line
calls.
81-11-01
DP Interdigit Time Selection
Select the DP Interdigit Time (minimum pause time between Dial Pulses).
81-11-02
Prepause Time Selection
Specify the loop open time for a hookflash signal sent to the Tie Line when the Recall key on a
Multiline Terminal is pressed. A Single Line Telephone (SLT) generates a hookflash to the Tie
line when a Single Line Telephone hookflash is assigned.
81-11-03
Tie Line - Line Answer Detect Time Selection
Specify the time before a Post IPK System answer (off-hook) is recognized as an answer.
81-11-04
Tie Line - Line Release Detect Time Selection
Specify the before the circuit disconnect detected on the Tie line on the distant system side is
recognized as Tie line release.
81-11-05
Incoming Signal Detect Time Selection
Specify the time after the incoming signal from another system is detected before the
acknowledge signal is sent out.
81-11-06
Loop Off-Guard Time Selection
Assign the loop off-guard time to prevent noise that could cause the system to be unable to
answer an incoming Tie line.
81-11-07
Length of Wink Signal Selection
Specify the time a wink pulse is sent to another system.
81-11-08
Length of Delay Signal Selection
Specify the time a delay pulse is sent to another system.
81-11-09
Incoming Interdigit Timeout Selection
Specify the time, in seconds, that an address signal is missing during the incoming call detection
process before an error tone is returned to the other system.
81-11-10
Wink/Delay Signal Detect Timeout Selection
Specify a maximum time, in seconds, for receiving an acknowledgment signal from a distant
system before sending a busy tone.
81-11-11
Disconnect Recognition Time Selection
Specify the minimum time before a disconnected circuit can be accessed again.
2 - 604