Document Revision 1
r
The PGD(2)-U10 ADP can only be connected to an ESIB(8)-U20 ETU. if the PGD(2)-U10
ADP is connected to an ESIE(8)-U20 ETU, the PGD(2)-U10 ADP will NOT be recognized.
When a ESIB(8)-U20 ETU has an ESIE(8)-U20 ETU installed [ESIB/E(16)], the PGD(2)-
r
U10 ADP will have both channels available for Paging, Music on Hold, External Ringers
and Door Box according to strapping on ports 1-8. The corresponding port on the ESIE(8)-
U20 ETU will not support a station or other hardware (it is used by the PGD(2)-U10 ADP for
channel 2).
When a ESIB(8)-U20 ETU is installed without an ESIE(8)-U20 ETU installed, a PGD(2)-
r
U10 ADP installed on ports 1~8 will be recognized, but only channel 1 on the PGD(2)-U10
ADP is supported. Channel 2 is not available.
r
ESIB(8)-U10 ETUs and ESIE(8)-U10 ETUs do not support the PGD(2)-U10 ADP.
A maximum of 56 PGD(2)-U10 ADP units can be installed in an IPK II system. Refer to the

Electra Elite IPK II System Hardware Manual for more information.
Default Setting
Disabled
System Availability
Terminals
None
Required Component(s)
PGD(2)-U10 ADP
Related Features
None
2 - 608
Electra Elite IPK II
Music on Hold

Advertisement

Table of Contents