If Program 21-01-10 is programmed with an entry other than "0", a call will not have a talk path
unless the user dials at least the number of digits entered in this option when placing an out
going call. This means that an entry of 4 or higher in this program will cause a problem when
dialing 911. Since it is only a 3-digit number, the call will not have a talk path, preventing the
emergency dispatcher from hearing the caller. It is recommended that this option be kept at its
default setting of "0" to prevent any problems with dialing 911.
Default Setting
Disabled
Programming
11-12-56
Service Code Setup (for Service Access) - E911 Alarm Shut Off
Select the Service Code (normally 786) that an extension user can dial to shut off the E911
Alarm Ring.
14-05-01
Trunk Groups
Assign the outbound trunks you want to use for E911 service to the same Trunk Group. (Trunk
Groups: 1~100)
14-06-01
Trunk Group Routing
Set up an outbound routing table for trunk groups assigned in Program 14-05. This program and
Program 21-02 are the minimum required if E911 must seize a line to dial.
Trunk Group Routes: 1~100
20-06-01
Class of Service for Extensions
Assign a Class of Service to an extension (1~15).
20-08-16
Class of Service Options (Outgoing Call Service - Display E911 Dialed Extension Name
and Number
In an extension's Class of Service, enable (1) or disable (0) the extension's ability to display the
name and number of the extension that activated E911 service. If disabled (0), the E911 Alarm
(set in Program 21-01-13) will never occur.
21-01-12
System Options for Outgoing Calls - Dial 911 Routing Without Trunk Access
If enabled (1), an extension user can dial 911 without first dialing a trunk access code or
pressing a line key. If disabled (0), an extension user must dial a trunk access code (e.g., 9) or
press a line key before dialing 911. If enabled, dialing 9+911 will still dial out.
21-01-13 : System Options for Outgoing Calls - Alarm Ring Timer (E911)
Use this option to set the duration of the E911 Alarm Ring Time (0-64800 seconds). If set for 0,
the E911 Alarm will not ring.
E911 Compatibility