4.
Remove shielding (4). (using a ladder)
5.
Loosen bolts (1) to remove elevator top plate (2).
6.
Check now distance X between the paddles and top
of clean grain elevator (using a small plate instead of
cover (2) Fig.5).
At the top left and right side of the grain elevator the
distance between paddle tip in its vertical position
with the top edge of the elevator housing may be
not larger than 3 mm (1/8 in) but not smaller than
1 mm (3/64 in). (turn the sprocket by hand to bring
the paddle in this position)
CROP PROCESSING - STORING AND HANDLING Grain storing
2 4/7/2006
K.60.B / 46
4
ZDA3674B
5
ZDA4149A_1360
6
ZDA3064A