Install the rotating connector.
Install the retaining plate and tighten three bolts (3).
8.
Install rotary separator drive belt (2) by using the
lever and adjust if necessary with nut (1) as de-
scribed in the CX-Operator's Manual; Section 4 -
"Lubrication and Maintenance", paragraph "Drive
belts and Chains - Right-hand side".
9.
Install the header and straw elevator intermediate
drive belt and tighten with nut (1) as described in the
CX-Operator's Manual; Section 4 - "Lubrication and
Maintenance", paragraph "Drive belts and Chains -
Right-hand side".
Install the hydraulic hose and tighten them with nut
(2).
IMPORTANT: The system does not need to bleed. The
plunger seals function as automatic breathers. Air will pass
but oil will not.
Next operation:
Install the grain elevator, refer to Grain elevator - Install (K.60.B.52 - F.10.A.15).