Parameter
Description
U885*
Switch setpoint input U886 in synchronism branch
Src SyncLocal ON
2885
U886*
Engagable offset distance prior to generation of the
Src SyncLocal
position setpoint
2886
Index 1: Offset distance
Index 2: Offset speed
U887*
Function parameter for stop cam operating mode
BPos OM Cam
0 = Edge change
1 = Static
2887
Note:
In the static stop cam operating mode an overtravel of the
cams is not supported which is why the cams have to be
executed up to the end stop!
In function diagram 789a (basic positioner)
U888*
Determines the direction of the position difference of the
S.DirPosEnSync
master value during synchronization.
2888
Sign of position difference of master value is processed
(U888.01 input value = 0) AND (U888.02 input value = 0)
(U888.01 input value = 1) AND (U888.02 input value = 1)
2.) Positive position differences of master value expected
(U888.01 input value = 1) AND (U888.02 input value = 0)
3.) Negative position differences of master value expected
(U888.01 input value = 0) AND (U888.02 input value = 1)
U890*
With this parameter, Y interpolation points 401 to 450 are
Tab Y401-Y450
entered in the table. The interpolation values are
evaluated only for U615 = 10 to 14. (The X nterpolation
2890
points are then assumed to be equidistant.)
Only for special applications after consultation with the
Applications Center.
Function diagram [839.4]
U891*
With this parameter, Y interpolation points 451 to 500 are
Tab Y451-Y500
entered in the table. The interpolation values are
evaluated only for U615 = 10 to 14.
2891
Only for special applications after consultation with the
Applications Center.
Function diagram [839.4]
U892*
With this parameter, Y interpolation points 501 to 550 are
Tab Y501-Y550
entered in the table. The interpolation values are
evaluated only for U615 = 10 to 14.
2892
Only for special applications after consultation with the
Applications Center.
Function diagram [839.4]
Siemens AG
6SE7087-6QX70 (Edition AL )
SIMOVERT MASTERDRIVES Compendium Motion Control
Data
Read/write
Init:
Menus:
Unit: -
- Parameter menu
Indices: -
+ Technology
Type: L2 ,B
+ Synchronism
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
index1: 0
Menus:
Unit: -
- Parameter menu
Indices: 2
+ Technology
Type: L2 ,K
+ Synchronism
,K
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
Init: 0
Menus:
Min: 0
- Parameter menu
Max: 1
+ Free blocks
Unit: -
- Upread/free access
Indices: -
Changeable in:
Type: O2
- Ready to switch on
index1: 0
Menus:
Unit: -
- Parameter menu
Indices: 2
- Upread/free access
Type: L2 ,B
Changeable in:
- Ready to switch on
index1: 0
Menus:
Min: -
- Parameter menu
2147483648
+ Technology
Max:
+ Synchronism
2147483647
- Upread/free access
Unit: -
Changeable in:
Indices: 50
- Ready to switch on
Type: I4
- Operation enabled
index1: 0
Menus:
Min: -
- Parameter menu
2147483648
+ Technology
Max:
+ Synchronism
2147483647
- Upread/free access
Unit: -
Changeable in:
Indices: 50
- Ready to switch on
Type: I4
- Operation enabled
index1: 0
Menus:
Min: -
- Parameter menu
2147483648
+ Technology
Max:
+ Synchronism
2147483647
- Upread/free access
Unit: -
Changeable in:
Indices: 50
- Ready to switch on
Type: I4
- Operation enabled
247