Instrument Messages
-200 to -299, Execution Errors
-200
Execution Error; Store ref
trace before turning on
Normalize
-200
Execution error; Sync word
was not found.
-200
Execution error; Trace file
contains no compatible
traces.
-200
Execution error; Trace file
created by incompatible
version of Phase Noise App
-201
Invalid while in local
-202
Settings lost due to rtl
-203
Command protected
-203
Command protected; feature
not licensed
-210
Trigger error
-211
Trigger ignored
-212
Arm ignored
-213
Init ignored
-214
Trigger deadlock
-215
Arm deadlock
Keysight N9010A EXA Service Guide
The Reference trace data must be stored in the Ref trace before you
turn on the Normalization function.
NADC & PDC: In an EVM measurement, the sync word is not found and
the synchronization cannot be established when Sync Word is
selected in the Burst Sync menu.
Flexible Digital Demodulation: The sync word cannot be detected
because of inappropriate parameter settings or incorrect signal.
The trace file may have been created by another version of the Phase
Noise personality, which uses a different trace format that is
incompatible with the version you are running. Please check you are
running the most up to date version of the personality.
The trace file may have been created by another version of the Phase
Noise personality, which uses a different trace format that is
incompatible with the version you are running. Please check you are
running the most up to date version of the personality.
The command cannot be executed while the instrument in Local
control.
A "return to local" control was forced and some settings were lost as a
result of this.
The command could not be executed because it is disabled. It was
disabled by licensing or password protection
The specified feature, for example "N9073A-TR2" is not licensed. The
license may have expired. You cannot use it until you get a license.
A trigger error has occurred, but the exact problem cannot be
specifically identified.
A GET, *TRG or other triggering signal was received, but it was ignored
because of timing considerations. For example, maybe the instrument
was not ready to respond when the command was received.
An arming signal was received, but it was ignored.
An initiate trigger/sweep request was received and ignored, because
another measurement was already in progress.
The trigger source for the initiation of a measurement is set to GET,
and the following measurement query was received. The measurement
cannot be started until a GET is received, but the GET would cause an
INTERRUPTED error.
The arm source for the initiation of a measurement is set to GET and
the following measurement query is received. The measurement
cannot be started until a GET is received and the GET would cause an
INTERRUPTED error.