Keysight Technologies X Series User Manual

Connector kit, signal analyzer
Hide thumbs Also See for X Series:

Advertisement

Quick Links

Keysight Technologies
Connector Kit
This documentation provides information for the following
X-Series Instruments:
N9041B UXA Signal Analyzer
User's Guide

Advertisement

Table of Contents
loading

Summary of Contents for Keysight Technologies X Series

  • Page 1 Keysight Technologies Connector Kit This documentation provides information for the following X-Series Instruments: N9041B UXA Signal Analyzer User's Guide...
  • Page 2 IMPLIED, WITH REGARD TO THIS MANUAL prior agreement and written consent from customarily provided to the public. AND ANY INFORMATION CONTAINED Keysight Technologies, Inc. as governed by Accordingly, Keysight provides the Software HEREIN, INCLUDING BUT NOT LIMITED TO United States and international copyright...
  • Page 3: Table Of Contents

    Contents 1 Keysight Connector Kit Connector Kit Overview Use of the Test Port Adaptors on Instrument RF Input 2 Input Connector Vise Assembly RF Input 1, 2.4 mm adaptor installation 2 Connector Care Visual Inspection Obvious defects or damage Connector Contacts Contact integrity Concentricity Making Connections...
  • Page 4 User's Guide...
  • Page 5: Keysight Connector Kit

    Keysight X-Series Signal Analyzer User's Guide 1 Keysight Connector Kit "Connector Kit Overview" on page 6 "Use of the Test Port Adaptors on Instrument RF Input 2" on page 7 "Input Connector Vise Assembly " on page 8...
  • Page 6: Connector Kit Overview

    1  Keysight Connector Kit Connector Kit Overview Connector Kit Overview The N9041B, Signal Analyzer has two input connectors, the right side RF Input 1 connector is a 2.4 mm male. The left side RF Input 2 connector is a special 1.0 mm male Keysight bulk head connector that has 14 mm wrench flats.
  • Page 7: Use Of The Test Port Adaptors On Instrument Rf Input 2

    1  Keysight Connector Kit Use of the Test Port Adaptors on Instrument RF Input 2 Use of the Test Port Adaptors on Instrument RF Input 2 Two, 1mm test port adaptors are supplied in the kit. The 1 mm female test port to 1 mm female adaptor is used as a connector saver to extend the lifespan of the instrument RF Input 2 connector.
  • Page 8: Input Connector Vise Assembly

    RF Input 2, the 1 mm input connector. The test port adaptors attach to the external threads on the instrument bulkhead input connector. However, if Keysight Technologies standard adaptors will be used instead of the test port adaptors, the use of the supplied Connector Vise assembly is recommended to prevent damage to the 1 mm input connector due to over torque.
  • Page 9 1  Keysight Connector Kit Input Connector Vise Assembly The Vise Clamp will now protect the input connector from damage when connections are made to the adaptor that exceed 4 inch-pounds torque. The Vise Clamp is only a rotation prevention device. It will not protect the input connector against damage from bending due to heavy side to side or up/down loading on the adaptor.
  • Page 10: Rf Input 1, 2.4 Mm Adaptor Installation

    1  Keysight Connector Kit RF Input 1, 2.4 mm adaptor installation RF Input 1, 2.4 mm adaptor installation Align the adaptor with the 2.4 mm input connector on the instrument and engage the nut of the input connector with the adaptor. Torque the bulkhead 2.4 mm input connector (with an 8 mm or 5/16"...
  • Page 11: Connector Care

    Keysight X-Series Signal Analyzer User's Guide 2 Connector Care "Visual Inspection" on page 12 "Connector Contacts" on page 13 "Making Connections" on page 15 "Cleaning Connectors" on page 16 "Replacement Parts" on page 17...
  • Page 12: Visual Inspection

    2  Connector Care Visual Inspection Visual Inspection Visual inspection and , if necessary cleaning should be done every time a connection is made. Metal particles from connector threads may fall into the connector when it is disconnected. One connection made with a dirty or damaged connector can damage both connectors beyond repair.
  • Page 13: Connector Contacts

    2  Connector Care Connector Contacts Connector Contacts Inspect the connector contacts for integrity. It is necessary to use good lighting (such as a halogen task light) to see the contacts. Notice the location of the cross hairs in relationship to the center of the figures. Contact integrity Refer to the following for visual guidelines when evaluating the contact integrity of a connector.
  • Page 14 2  Connector Care Connector Contacts Male connector: User's Guide...
  • Page 15: Making Connections

    2  Connector Care Making Connections Making Connections Good connections require a skilled operator. Instrument sensitivity and coaxial connector mechanical tolerances are such that slight errors in operator technique can have a significant effect on measurements and measurement uncertainties. The most common cause of measurement error is poor connections. Connection Procedure 1.
  • Page 16: Cleaning Connectors

    2  Connector Care Cleaning Connectors Cleaning Connectors Basic Cleaning Procedure 1. Inspect the connectors for dust, dirt, metal fragment, oils or film, and debris. 2. Blow off any dust with a filtered, clean supply of compressed air. 3. Add a few drops of high-purity isopropyl alcohol to a small cleaning swab (do not apply alcohol directly to the parts).
  • Page 17: Replacement Parts

    2  Connector Care Replacement Parts Replacement Parts Description Ordering number Test Port Adaptor, 1mm (f) to 1mm (f) Y1900B Test port Adaptor, 1mm (f) to 1.85mm (f) Y1901B 2.4 mm (f) to 2.4 mm (f), 11900B 2.4 mm (f) to 2.92 mm (f), 11904B Wrench-Torque Special Double-end 14mm-open end 4 and 8710-2819...
  • Page 18 This information is subject to change without notice. © Keysight Technologies 2019 Edition 1, July 2019 N9041-90006 www.keysight.com...

This manual is also suitable for:

N9041b uxa

Table of Contents