Goodrive35 Series Closed-loop Vector Control VFD
Code
Fault
Inverter module
OH2
overheated
EF
External fault
485
CE
communication
fault
Current-detecting
ItE
fault
Motor-autotuning
tE
fault
EEPROM
EEP
operation fault
PID feedback
PIDE
outline fault
bCE
Brake unit fault
Running time
END
arrival
Electrical
OL3
overload
PCE
Keypad
Cause
The time of overload running is
too long.
SI external fault input terminals
act
The
baud
rate
incorrect.
Fault
occurs
communication wiring.
 Communication address is wrong.
There is strong interference to
the communication.
The connection of the control
board is not good
Hall components is broken
The
modifying
abnormal.
The motor capacity does not
comply with VFD capability
The rated parameter of the motor
does not set correctly.
The
offset
between
parameters from autotune and
the standard parameter is huge
Autotune overtime
Error of controlling the write and
read of the parameters
Damage to EEPROM
PID feedback offline
PID feedback source disappear
Brake circuit fault or damage to
the brake pipes
brake
External
insufficient
The actual running time of the
VFD is above the internal setting
running time.
 VFD
will
report
pre-alarm based on the set value.
The connection of the keypad Check the keypad wires and ensure
Lower the ambient temperature
Check the external device input
setting
is
Set proper baud rate
Check
to
the
connection distribution
Set proper communication address.
Chang or replace the connection
distribution
anti-interference capability.
Check the connector and re-plug
Change the Hall
circuit
is
Change the main control panel
Change the VFD mode
Set the rated parameter according to
the motor name plate
Empty the motor load and re-identify
the
Check the motor connection and set
the parameter.
Check if the upper limit frequency is
above 2/3 of the rated frequency.
Press STOP/RST to reset
Change the main control panel
Check the PID feedback signal
Check the PID feedback source
Check the brake unit and , change
new brake pipe
resistor
is
Increase the brake resistor
Ask for the supplier and adjust the
setting running time.
overload
Check the load and the overload
pre-alarm threshold.
202
Fault tracking
Solution
the
communication
or
improve
the

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Goodrive35 Series and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Goodrive gd35-1r5g-4-c1Goodrive gd35-2r2g-4-c1 gd35-2r2g-4-d1Goodrive gd35-1r5g-4-d1Goodrive gd35-2r2g-4-h1Goodrive gd35-004g-4-c1Goodrive gd35-1r5g-4-h1 ... Show all

Table of Contents

Save PDF