Goodrive35 Series Closed-loop Vector Control VFD
Terminal function 16
OFF
ON
OFF
Multi-stage speed
terminal 1
Terminal function 17
OFF
OFF
ON
Multi-stage speed
terminal 21
Terminal function 18
OFF
OFF
OFF
Multi-stage speed
terminal 3
Terminal function 19
OFF
OFF
OFF
Multi-stage speed
terminal 4
0
1
2
Multi-stage
speed
Multi-stage
speed 0
Multi-stage
speed 1
Running command
Terminal function 16
Multi-stage speed 1
Terminal function 17
Multi-stage speed 2
Terminal function 18
Multi-stage speed
terminal 3
Terminal function 19
Multi-stage speed
terminal 1
Terminal function 16
OFF
ON
OFF
Multi-stage speed
terminal 1
Terminal function 17
OFF
OFF
ON
Multi-stage speed
terminal 2
Terminal function 18
OFF
OFF
OFF
Multi-stage speed
terminal 3
Terminal function 19
ON
ON
ON
Multi-stage speed
terminal 4
Multi-stage
8
9
10
speed
Relative parameters list:
Function
code
P10.02
Multi-step speed 0
P10.03
The running time of step 0 0.0–6553.5 s (min)
P10.04
Multi-step speed 1
P10.05
The running time of step 1 0.0–6553.5 s (min)
P10.06
Multi-step speed 2
P10.07
The running time of step 2 0.0–6553.5 s (min)
P10.08
Multi-step speed 3
P10.09
The running time of step 3 0.0–6553.5 s (min)
P10.10
Multi-step speed 4
P10.11
The running time of step 4 0.0–6553.5 s (min)
P10.12
Multi-step speed 5
P10.13
The running time of step 5 0.0–6553.5 s (min)
P10.14
Multi-step speed 6
P10.15
The running time of step 6 0.0–6553.5 s (min)
ON
OFF
ON
OFF
ON
ON
ON
OFF
OFF
ON
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
3
4
5
6
7
Multi-stage
speed 15
OFF
ON
ON
OFF
ON
OFF
ON
ON
ON
OFF
OFF
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
11
12
13
14
15
Name
P10.02 multi-stage speed 0
BIT0
P10.03 the running time of stage 0
BIT1
P10.04 multi-stage speed 1
BIT2
P10.05 the running time of stage 1
BIT3
P10.06 multi-stage speed 2
BIT4
P10.07 the running time of stage 2
BIT5
P10.08 multi-stage speed 3
BIT6
P10.09 the running time of stage 3
BIT7
P10.10 multi-stage speed 4
BIT8
P10.11 the running time of stage 4
BIT9
P10.12 multi-stage speed 5
BIT10
P10.13 the running time of stage 5
BIT11
P10.14 multi-stage speed 6
BIT12
P10.15 the running time of stage 6
BIT13
P10.16 multi-stage speed 7
BIT14
P10.17 the running time of stage 7
BIT15
P10.18 multi-stage speed 8
BIT0
P10.19 the running time of stage 8
BIT1
P10.20 multi-stage speed 9
BIT2
P10.21 the running time of stage 9
BIT3
P10.22 multi-stage speed 10
BIT4
P10.23 the running time of stage
BIT5
10
P10.24 multi-stage speed 11
BIT6
P10.25 the running time of stage
BIT7
11
P10.26 multi-stage speed 12
BIT8
P10.27 the running time of stage
BIT9
12
P10.28 multi-stage speed 13
BIT10
P10.29 the running time of stage
BIT11
13
P10.30 multi-stage speed 14
BIT12
P10.31 the running time of stage
BIT13
14
P10.32 multi-stage speed 15
BIT14
P10.33 the running time of stage 15
BIT15
Detailed instruction of parameters
-100.0–100.0%
-100.0–100.0%
-100.0–100.0%
-100.0–100.0%
-100.0–100.0%
-100.0–100.0%
-100.0–100.0%
184
Basic operation instruction
P10.34
The ACC/DEC time selection
of Stage 0~7 of PLC
00
P00.10 ACC time 1
P00.12 DEC time 1
01
P08.00 ACC time 2
P08.01 DEC time 2
10
P08.02 ACC time 3
P08.03 DEC time 3
11
P08.04 ACC time 4
P08.15 DEC time 4
The ACC/DEC time selection
of Stage 8~15 of PLC
00
P00.10 ACC time 1
P00.12 DEC time 1
01
P08.00 ACC time 2
P08.01 DEC time 2
10
P08.02 ACC time 3
P08.03 DEC time 3
11
P08.04 ACC time 4
P08.15 DEC time 4
Valid
Frequency
retention
Invalid
Multi-stage speed
output
Default
value
0.0%
0.0 s
0.0%
0.0 s
0.0%
0.0 s
0.0%
0.0 s
0.0%
0.0 s
0.0%
0.0 s
0.0%
0.0 s

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Goodrive35 Series and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Goodrive gd35-1r5g-4-c1Goodrive gd35-2r2g-4-c1 gd35-2r2g-4-d1Goodrive gd35-1r5g-4-d1Goodrive gd35-2r2g-4-h1Goodrive gd35-004g-4-c1Goodrive gd35-1r5g-4-h1 ... Show all

Table of Contents

Save PDF