INVT Goodrive35 Series Operation Manual page 166

Closed-loop vector control vfd
Table of Contents

Advertisement

Goodrive35 Series Closed-loop Vector Control VFD
Function
code
P01.18
running protection when
Action if running frequency<
P01.19
lower limit frequency (valid >0)
P01.20
Hibernation restore delay time
P01.21
Restart after power off
The waiting time of restart after
P01.22
P01.23
P01.24
Delay time of the stopping speed 0.00–60.00 s
P05.01–P
Digital input function selection
05.09
P08.00
P08.01
P08.02
P08.03
P08.04
P08.05
Name
Terminal
powering on
power off
Start delay time
ACC time 2
DEC time 2
ACC time 3
DEC time 3
ACC time 4
DEC time 4
Detailed instruction of parameters
0: The terminal running command is
invalid when powering on
1: The terminal running command is
valid when powering on
0: Run at the lower-limit frequency
1: Stop
2: Hibernation
3: Run at zero frequency
0.0–3600.0s (valid when P01.19=2)
0: Disable
1: Enable
0.0–3600.0 s (valid when P01.21=1)
0.00–60.00 s
1: Forward rotation operation
2: Reverse rotation operation
4: Forward rotation jogging
5: Reverse rotation jogging
6: Coast to stop
7: Fault reset
8: Operation pause
21: ACC/DEC time option 1
22: ACC/DEC time option 2
30: ACC/DEC prohibition
0.0–3600.0 s
0.0–3600.0 s
0.0–3600.0 s
0.0–3600.0 s
0.0–3600.0 s
0.0–3600.0 s
159
Basic operation instruction
Default
value
0
0
0.0s
0
1.0s
0.00s
0.00s
Depend on
model
Depend on
model
Depend on
model
Depend on
model
Depend on
model
Depend on
model

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Goodrive35 Series and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Goodrive gd35-1r5g-4-c1Goodrive gd35-2r2g-4-c1 gd35-2r2g-4-d1Goodrive gd35-1r5g-4-d1Goodrive gd35-2r2g-4-h1Goodrive gd35-004g-4-c1Goodrive gd35-1r5g-4-h1 ... Show all

Table of Contents

Save PDF