Release/apply brake
• p0855
• p0858
• p1216
• p1217
• p1218[0...1]
• p1219[0...3 ]
• p1220
• p1221
• p1277
• p1279
Brake monitoring functions
• p1222
• p1223
Configuration, control/status words
• p1215
• r1229
• p1275
• p1278
9.3.4

Extended monitoring functions

Description
The "extended monitoring functions" function module enables additional monitoring
functions:
● Speed setpoint monitoring: |n_set| ≤ p2161
● Speed setpoint monitoring: n_set > 0
● Load monitoring
Inverter chassis units
Operating Instructions, 07/2016, A5E00331449A
BI: Unconditionally release holding brake
BI: Unconditionally apply holding brake
Motor holding brake release time
Motor holding brake closing time
BI: Release motor holding brake
BI: Immediately apply motor holding brake
CI: Release motor holding brake, signal source, threshold
Release motor holding brake, threshold
Motor holding brake, delay, braking threshold exceeded
BI: Motor holding brake OR/AND logic operation
BI: Motor holding brake, feedback signal, brake closed
BI: Motor holding brake, feedback signal, brake released
Motor holding brake configuration
CO/BO: Motor holding brake status word
Motor holding brake control word
Motor holding brake type