Register Description
40342
Output frequency
40343
Output voltage
40344
DC-link voltage
40345
Actual current value
40347
Actual active power
40349
Control priority
Fault diagnostics
40400
Failure number, index 0
40401
Failure number, index 1
40402
Failure number, index 2
40403
Fault number, index 3
40404
Fault number, index 4
40405
Fault number, index 5
40406
Fault number, index 6
40407
Fault number, index 7
40408
Alarm number
40409
Actual alarm code
40499
PRM ERROR code
Technology controller
3)
40500
Technology controller enable
40501
Technology controller MOP
Adapt technology controller
40510
Time constant for actual-value filters
of the technology controller
40511
Scaling factor for actual value of the
technology controller
40512
Proportional amplification of the tech-
nology controller
40513
Integral time of the technology con-
troller
40514
Time constant D-component of the
technology controller
40515
Max. limit of technology controller
40516
Min. limit technology controller
PID diagnostics
40520
Effective setpoint acc. to internal
technology controller MOP ramp-
function generator
40521
Actual value of technology controller
after filter
40522
Output signal technology controller
The technology controller parameters can only be accessed if, in the STARTER project, also the "Technology controller"
1)
function module is activated.
Inverter chassis units
Operating Instructions, 07/2016, A5E00331449A
Ac-
cess
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R/W
R/W
1)
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R
R
R
6.11 Communication via MODBUS TCP
Unit
Scaling
ON/OFF text
or Value range
Hz
100
- 327.68 ... 327.67 r0024
V
1
0 ... 65535
V
1
0 ... 65535
A
100
0 ... 655.35
kW
100
0 ... 655.35
-
1
HAND
-
1
0 ... 65535
-
1
0 ... 65535
-
1
0 ... 65535
-
1
0 ... 65535
-
1
0 ... 65535
-
1
0 ... 65535
-
1
0 ... 65535
-
1
0 ... 65535
-
1
0 ... 65535
-
1
0 ... 65535
-
1
0 ... 255
-
1
0 ... 1
%
100
-200.0 ... 200.0
-
100
0.00 ... 60.0
%
100
0.00 ... 500.00
-
1000
0.000 ... 65.535
s
1
0 ... 60
-
1
0 ... 60
%
100
-200.0 ... 200.0
%
100
-200.0 ... 200.0
%
100
-100.0 ... 100.0
%
100
-100.0 ... 100.0
%
100
-100.0 ... 100.0
Operation
Data / parameter
r0025
r0026
r0027
r0032
AUTO
r0807
r0947[0]
r0947[1]
r0947[2]
r0947[3]
r0947[4]
r0947[5]
r0947[6]
r0947[7]
r2110[0]
r2132
-
p2200, r2349.0
p2240
p2265
p2269
p2280
p2285
p2274
p2291
p2292
r2250
r2266
r2294