Functions, monitoring, and protective functions
9.2 Drive functions
Parameter
• p0010
• p0100
• p0349
• p0505
• p0595
• p0596
• p2000
• p2001
• p2002
• p2003
• r2004
• p2005
• p2006
• p2007
9.2.17

Simple brake control

Description
The "Simple brake control" is used exclusively for the control of holding brakes. The holding
brake is used to secure drives against unwanted motion when deactivated.
The control command for releasing and applying the holding brake is transmitted directly to
the converter via DRIVE-CLiQ from the Control Unit, which logically combines the signals
with the system-internal processes and monitors these signals.
The converter then performs the action and controls the output for the holding brake
appropriately.
The operating principle of the holding brake can be configured using parameter p1215.
422
Commissioning parameter filter
IEC/NEMA mot stds
Unit system, motor equivalent circuit diagram data
Unit system selection
Technological unit selection
Technological unit reference variable
Reference speed reference frequency
Reference voltage
Reference current
Reference torque
Reference power
Reference angle
Reference temperature
Reference acceleration
Inverter chassis units