Note
List of the exceptions when know-how protection is activated
A list of the adjustable parameters which, in spite of activated know-how protection, can be
changed, is provided in the List Manual.
The list has the designation "KHP_WRITE_NO_LOCK".
Functions, which cannot be executed when know-how protection is active
The following functions cannot be executed when know-how protection is active:
● Download
● Automatic controller setting
● Stationary/rotating measurement
● Clear fault buffer
● Create acceptance documentation
Functions that can be executed optionally when know-how protection is active
The functions listed below can be executed for activated know-how protection provided
diagnostic functions were permitted when it was activated:
● Trace function
● Function generator
● Measuring functions
Setting parameters, which can only be read when know-how protection is active
The following setting parameters cannot be changed, but can be read, when know-how
protection is activated:
● Motor parameters (p0100, p0300, p0304, p0305, p0349)
● Data sets (p0120, p0130, p0140, p0150, p0170, p0180)
● Encoder type (p0400)
● Reference quantities (p2000, p2001, p2002, p2003, p2005, p2006, p2007)
These parameters are shown in STARTER in the expert list with a gray background.
Inverter chassis units
Operating Instructions, 07/2016, A5E00331449A
Functions, monitoring, and protective functions
9.2 Drive functions