Switch
SW 2-1
SW 2-2
___________________________________________________________________________________
System Hardware Manual
8.9.2

Installation

Basic Port Package
Only one VMP ETU can be installed in slots S1~S8.
This ETU shares the total number of station ports in the system. The
system is limited by 256 stations.
Expanded Port Package
Only one VMP ETU can be installed in slots S1~S8.
This ETU shares the total number of station ports in the system. The
system is limited by 256 stations.
8.9.3
Switch Settings
The following default switch settings are used for the
ETU. Typically these settings should remain at factory default.
Table 6-65 Switch Settings for VMP(4)/(8)-U( ) ETU
Default
Setting
SW 1
Off
Resets the ETU. Leave at factory default setting.
Off
Not used for IVR ETU. Leave at factory default setting.
Restores the ETU to factory default settings if set to On.
Off
Leave at factory default unless factory defaults must be restored, then set
SW2-2 and SW2-3 to On.
SW2-3
Off
Restores the ETU to factory default settings if set to On.
Leave at factory default unless factory defaults must be restored, then set
SW2-2 and SW2-3 to On.
SW3
Off
Toggles to switch the IVR application On or Off.
When installing this ETU, make all ETU DIP switch setting
changes before inserting it in the KSU. Ensure that KSU
is off.