Environmental Conditions; Power Requirements; Power Supply Inputs; Power Supply Consumption - NEC Electra Elite IPK II System Hardware Manual

Hide thumbs Also See for Electra Elite IPK II:
Table of Contents

Advertisement

Electra Elite IPK II
___________________________________________________________________________________
5.3
___________________________________________________________________________________
System Hardware Manual
5.2.2

Environmental Conditions

Temperature
Operating:
Long Term:
Humidity
Operating:

Power Requirements

5.3.1

Power Supply Inputs

AC input requirements for the system are listed below.
AC Input [P64-U( ) PSU]
117 Vac ± 10%
60 Hz ± 10%
Single Phase
7.5A circuit
A dedicated outlet, separately fused and grounded
5.3.2

Power Supply Consumption

The power consumption for the Electra Elite IPK II system is listed in
Table 3-10 Power
Basic KSU – B64-U20 KSU
Basic KSU + Expansion KSU
Basic KSU + 2 Expansion KSUs
When replacing fuses, refer to the specifications in
Replacement.
+32°F ~ +104°F (0°C ~ 40°C)
+50°F ~ +90°F (10°C ~ 32.2°C)
10% ~ 90% noncondensing
Consumption.
Table 3-10 Power Consumption
Maximum
KSU
RMS
Current
2.5 A
5.0 A
7.5 A
Document Revision 3
Watts
Watts
Used
Used
(Idle)
(Maximum)
120
230
240
460
360
690
Table 3-11 Fuse
3 - 25