Installation; Switch Settings - NEC Electra Elite IPK II System Hardware Manual

Hide thumbs Also See for Electra Elite IPK II:
Table of Contents

Advertisement

Electra Elite IPK II
___________________________________________________________________________________
___________________________________________________________________________________
System Hardware Manual
6.3.2

Installation

Basic Port Package
A maximum of seven ESIB(8)-U20 ETUs can be installed in slots
S1~S8.
The maximum number of ESIB(8)-U20 ETUs that can be installed
depends on other station ETUs installed. The system is limited by 64
trunk and station ports combined. This ETU shares the total number
of station ports in the system.
Calculating maximum capacity is based on the system having a
minimum of eight Electronic Station Interface (ESI) ports, four trunk
ports and a PKUII-U Unit installed.
Expanded Port Package
A maximum of 23 ESIB(8)-U20 ETUs can be installed in slots
S1~S8.
The maximum number of ESIB(8)-U20 ETUs that can be installed
depends on other station ETUs installed. The system is limited by
256 stations. This ETU shares the total number of station ports in
the system.
Calculating maximum capacity is based on the system having a
minimum of eight Electronic Station Interface (ESI) ports, four trunk
ports and a PKUII-U Unit installed.
Refer to Chapter 3 System Specifications, Section 4 KSU
Power-Based Calculator Chart for Universal Slots.
6.3.3

Switch Settings

SW1 resets the ETU.
Refer to the table below for ESIBSW functions.
Jumper
ESIB-U1X Mode:
ESIB ETU operates as an
ESIB-U10
ESIBSW
ESIB-U2X Mode:
ESIB ETU operates as an
ESIB-U20 with support for B1
and B2 channels.
When installed in an Electra Elite IPK, this jumper must be set to

U10 Mode (pins 2 and 3).
Setting
No Ancillary device support
B1 and B2 channel support
available. For B2 Channel
Function, the ESIE(8)-U20
must be installed.
Document Revision 3
Description
6 - 67