Installation; Switch Settings - NEC Electra Elite IPK II System Hardware Manual

Hide thumbs Also See for Electra Elite IPK II:
Table of Contents

Advertisement

Document Revision 3
___________________________________________________________________________________
___________________________________________________________________________________
6 - 138
7.6.2

Installation

The VMS(2)-U10 ETU has two channels of built-in Voice Mail.
The VMS(4)-U10 ETU has four channels of built-in Voice Mail.
The VMS(8)-U10 ETU has eight channels of built-in Voice Mail.
Basic Port Package
Only one VMS(2)/(4)/(8)-U( ) ETU or one VMS-U30 ETU can be
installed in each system in slots S1~S8.
This ETU shares the total number of station ports in the system.
Expanded Port Package
Only one VMS(2)/(4)/(8)-U( ) ETU or one VMS-U30 ETU can be
installed in each system in slots S1~S8.
This ETU shares the total number of station ports in the system.
Each system can support only one CMS, CTI/VP, CTP, FMS, VMS,
or VMP ETU.
When installing this ETU, make all ETU DIP switch setting
changes before inserting it in the KSU. Ensure that the
KSU is off.
7.6.3

Switch Settings

Refer to
Table 6-47 VMS(2)/(4)/(8)-U( ) ETU DIP Switch
(Revision Q30931 v 6.65 or lower). For Revision Q30931 v 6.68 or
higher, refer to
Functions.
Table 6-47 VMS(2)/(4)/(8)-U( ) ETU DIP Switch Settings
Switch
1
Normally Off.
(On to enable COM1.)
2
Normally Off.
When 1 and 2 are both On, COM1 is enabled for HOSTKEY
and the VM application is stopped for Maintenance.
3
On to enable COM2 for remote RS-232/RJ-11.
Off to allow COM1 local connection.
4
Not Used.
Used for Revision Q30931 v 6.65 or lower.

Table 6-48 VMS(2)/(4)/(8)-U( ) ETU DIP Switch
Description
Electra Elite IPK II
Settings.
Installing ETUs (Circuit Cards)