Projector Feet - Christie CP2000-M Service Booklet

Hide thumbs Also See for CP2000-M:
Table of Contents

Advertisement

6. Use a #2 Phillips™ to remove the 13 screws securing the front lamp cover and lamp shield to the
reflector assembly (Figure 2-23).
7. Reverse the above steps to reinstall the lamp cover, shield and reflector assembly.
8. Perform LampLOC™ alignment. For details, refer to the CP2000M-MR User Manual (020-
100123-xx).

2.6.5 PROJECTOR FEET

(15 minutes for 1 foot + 5 minutes per additional foot + 30 minutes to tweak masking)
1. Remove top lid. Refer to
2. Prop up the appropriate end of the projector or shift the projector off the table/pedestal to achieve
proper clearance.
3. To remove the front feet, 15 centimeters (6") of clearance is required. To remove the rear feet, 23
centimeters (9") is required.
4. Use a 17mm socket to remove the locking nut on the foot.
5. Use a 19mm wrench to remove the entire foot.
6. Reverse the above steps to reinstall the feet.
7. Tweak masking. For details, refer to the CP2000-M/MR User Manual (020-100123-xx).
CP2000-M/MR Service Booklet
020-100220-02 Rev. 1 (07/08)
F
2-23 F
L
IGURE
RONT
AMP
2.5.5 Top Lid, on page
Section 5: Parts and Module Replacement
C
& L
S
OVER
AMP
HIELD
2-10.
2-23