9. Before the old lamp is put into its case ensure the cathode nut is placed back onto the lamp. Follow
all local safety standards for proper disposal.

INSTALLING A NEW LAMP

• Remove the cathode clamp from the lamp before removing it from
its case.
• Hold the anode end of the lamp in your left hand and angle it up
through the hole in the back of the reflector assembly. Insert your
right index and middle finger through the back front of the reflector
and guide the lamp onto the cathode holder. Be careful not to hit the
lamp against the reflector.
• Hand-tighten the cathode clamp onto the cathode end of the lamp.
• Tighten the cathode
• Align the ring terminal on the anode wire with the mounting
position, ensuring the crimped side of the wire is facing out
(Figure 2-17). Tighten the anode nut.
• Ensure LampLOC™ is adjusted
2.6

LAMP COMPARTMENT

2.6.1 SAFETY SHIELD

The safety shield is positioned above the lamp
reflector and is used to block UV light.
(5 minutes)
1. Open the rear lamp door via the low security
key.
2. Use a #1 Phillips™ to loosen the 3
thumbscrews (Figure 2-18).
3. Remove the safety shield.
4. To reinstall, reverse the above steps.
CP2000-M/MR Service Booklet
020-100220-02 Rev. 1 (07/08)
nut.
Section 5: Parts and Module Replacement
F
IGURE
F
2-18 S
IGURE
AFETY
2-17 A
W
NODE
IRE
S
HIELD
2-19

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cp2000-mr

Table of Contents