Section 8: Specifications
5.4

POWER REQUIREMENTS

5.4.1 Standard Mode (uses line cord provided)

Voltage Range:
Line Frequency:
Inrush Current:
Current Consumption:
Power Consumption:
Current Rating of AC Input:
Line Cord Plug Type

5.4.2 UPS (Uninterruptible Power Supply) Mode

Activation
UPS Inlet Connector
(rating for powering main electronics on projector)
Inlet Rating
Lamp Power Supply Inlet Rating
5.5

LAMP

Type
Power (software adjustable)
Average Life (See Notes 1, 2)
Warm-up time to full brightness
Wait time between lamp strikes (see Note 3)
NOTES: 1) Based on use at nominal rated power; operating at greater than nominal power reduces
lamp life. 2) End of life is defined as the point where the amount of flicker is above the manufacturer's
threshold; or the lamp fails to ignite; or brightness is <50% of initial brightness. Duty cycle 2 hours
ON/0.5 hours OFF. 3) Hot re-strike (less than the minimum time between strikes) reduces lamp life;
therefore it is strongly NOT recommended.
5-6
200 - 240 VAC
50 Hz - 60 Hz nominal
< 85 A max.
16 A max. (at 200 VAC)
3200 W max.
IEC-320-C19/20A (required by regulatory)
NEMA 6-20P
Discrete switch above power inlet cord(s)
IEC-320-C13/10A, 240VAC
100-240VAC, 8A (refer to license label)
IEC-320-C19/20A (required by regulatory)
(also required)
CDXL-20SD, Xenon Short Arc Lamp
1000W min. - 2000W nom. - 2100W max.
1500 hours @ 2000W
20 minutes max.
2 minutes min.