Section 5: Parts and Module Replacement

2.8.8 YELLOW NOTCH FILTER (YNF)

The YNF is located on the IOS behind the contrast aperture.
(50 minutes; includes 30 minute calibration)
1. Remove top lid. Refer to
2. Use a 2mm Allen key to remove the 3 hex screws securing the YNF to the IOS (Figure 2-65). If
necessary, loosen the center nut.
3. Carefully pull the filter out of the IOS.
4. Reverse the above steps to install.
5. Green primary and MCGD must be calibrated after installation. For details, refer to the CP2000-
M/MR User Manual (020-100123-xx).
2-52
2.5.5 Top Lid, on page
2-10.
F
2-65 R
IGURE
EMOVE
YNF
CP2000-M/MR Service Booklet
020-100220-02 Rev. 1 (07/08)