Remove Lamp - Christie CP2000-M Service Booklet

Hide thumbs Also See for CP2000-M:
Table of Contents

Advertisement

Section 5: Parts and Module Replacement

2.5.14 REMOVE LAMP

Always wear protective safety clothing and a face shield when handling the lamp.
Never attempt to remove the lamp when it is hot. The lamp is pressurized and may
explode, causing personal injury or death, and/or property damage. Allow the lamp to
cool completely before handling.
Improper installation of the lamp can cause serious damage to the projector.
(20 minutes; includes 10 minute LampLOC™ alignment)
1. Ensure power to the projector is disabled. Allow the fans to automatically turn OFF before
disconnecting the AC power cord and opening the projector. This takes approximately 15 minutes.
2. Open the lamp door skin.
3. Use a #1 Phillips™ to remove the 2 captive screws securing the lamp access door.
4. Remove the cathode clamp from the lamp (Figure 2-16, F).
5. Using the Allen™ key, provided on the rear door, loosen the nut on the cathode end of the lamp
(Figure 2-16, E).
6. Use a #3 Phillips™ to loosen the nut securing the anode wire (Figure 2-16, D).
F
7. Remove the Ballast Terminal Insulator by unscrewing the 2 black captive screws (#2 Phillips™)
and pulling it straight out (Figure 2-16, C).
8. Hold the lamp from the anode end and carefully slide out ensuring not to make contact with the
reflector (Figure 2-16, A). Using your other hand guide the cathode end out of the reflector, on an
angle.
2-18
2-16 L
A
IGURE
AMP
SSEMBLY
DANGER
WARNING
A
Reflector
B
Anode Wire
C
Captive Screws x2
D
Anode Nut
E
Cathode Nut
F
Cathode Clamp
G
Cathode Wire
CP2000-M/MR Service Booklet
020-100220-02 Rev. 1 (07/08)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cp2000-mr

Table of Contents