Section 7: Serial Communications
Table 4.1 Function Codes
EXAMPLES:
(LMV 1000 1500 500 -500) Move lens to horizontal/1000, vertical/15000, zoom/500 and focus -500.
Local Settings (LOC)
DESCRIPTION
Set the localization options such as Language and display options for temperature units.
SUBCODE
LANG
TEMP
TIME
EXAMPLES:
(LOC+TIME 1) Set time zone to standard 12 hour
(LOC+TIME?1) Get list of formats
(LOC+TIME?)(LOC+TIME!001) Get time format
Lamp Changed (LPC)
DESCRIPTION
Record current lamp information into the lamp history, then start a new entry. Set lamp information of a new lamp
type ID, serial number, and pre-used hours.
SUBCODE
LPID
PREV
SERL
EXAMPLES:
(LPC+LPID "CDX-30") set lamp type ID
(LPC+SERL "CDX30-001") set lamp serial number
(LPC 1) save information to lamp history
Lamp Hours (LPH)
DESCRIPTION
Read only control, get information on installed lamp.
SUBCODE
FLSK
FRSK
LPOF
None
TLSK
4-12
DESCRIPTION OF USE
Set the primary language. 0 - English.
Set the temperature units. 0 - Celsius. (Choices are Deferred past
V1.0)
Set Time format. 0 - 24 hour, 1 - 12 hour.
DESCRIPTION OF USE
Set lamp type ID for the new lamp
Set lamp previous lamp hours for the new lamp
Set lamp serial number for the new lamp
DESCRIPTION OF USE
Return Total failed lamp strikes on the installed lamp.
Return Total failed lamp restrikes on the installed lamp.
Return Total lamp unexpected off times on the installed lamp.
Return Lamp usage for current lamp in hours.
Return Total lamp strikes on the installed lamp.