2.6.9 LAMP BALLAST - FANS 1 AND 2
There are 2 fans on the lamp ballast. NOTES: 1) If 1 fan fails both must be replaced. 2) The fans can
be replaced without having to replace the ballast.
(35 minutes; includes 10 minute LampLOC™ alignment)
1. Remove lamp ballast. Refer to
2. Holding the fan from the bottom pull up on the top to unmount the fan from the 4 rubber isolators
(Figure 2-30).
3. Disconnect the fan harnesses from the ballast.
4. Reverse the above steps to reinstall the lamp ballast.
5. Disconnect the fan from the lamp ballast.
6. Reverse the above steps to reinstall. NOTE: Use needle nose pliers to pull the rubber isolators
through the fan mounting holes.
CP2000-M/MR Service Booklet
020-100220-02 Rev. 1 (07/08)
Section 5: Parts and Module Replacement
2.6.8 Lamp Ballast, on page
F
2-30 B
F
IGURE
ALLAST
AN
2-25.
2-27