Christie CP2000-M Service Booklet page 97

Hide thumbs Also See for CP2000-M:
Table of Contents

Advertisement

Section 7: Serial Communications
Table 4.1 Function Codes
EXAMPLES:
(NET+ETH0 "192.168.1.35") - Set new IP address on the first ethernet controller
(NET+ETH1 "192.168.1.36") - Set new IP address on the second ethernet controller
(NET+GATE "192.168.0.1") - Set the gateway
(NET+SUB0 "255.255.255.0") - Set the subnet mask on the first ethernet controller
(NET+HOST "MyHostName") - Set the host name
(NET+DOMA "MyDomainName") - Set the domain name
(NET+ETH0 ?) - Retrieve IP address from first controller. (NET+ETH0! 192.168.1.35)
(NET+ETH0 ?) - Retrieve IP address from second controller. (NET+ETH1! 192.168.1.36)
(NET+MAC0 ?) - Retrieve MAC address from first controller. (NET+MAC0! 00:12:3F:7B:76:B4)
(NET+MAC1 ?) - Retrieve MAC address from second controller. (NET+MAC1! 00:12:3F:7B:76:B5)
(NET+GATE ?) - Retrieve default gateway. (NET+GATE! 192.168.0.1)
(NET+ETH0 "192.168.1.35") - Set new IP address on the MGMT ethernet controller
(NET+ETH1 "192.168.1.36") - Set new IP address on the AUX ethernet controller
(NET+SUB0 "255.255.255.0") - Set the subnet mask on the MGMT ethernet controller
(NET+ETH0 ?) - Retrieve IP address from MGMT controller. (NET+ETH0! 192.168.1.35)
(NET+ETH0 ?) - Retrieve IP address from AUX controller. (NET+ETH1! 192.168.1.36)
(NET+MAC0 ?) - Retrieve MAC address from MGMT controller. (NET+MAC0! 00:12:3F:7B:76:B4)
(NET+MAC1 ?) - Retrieve MAC address from AUX controller. (NET+MAC1! 00:12:3F:7B:76:B5)
(NET+GATE ?) - Retrieve default gateway. (NET+GATE! 192.168.0.1)
(NET+DLP0 "192.168.206.10") Set Cinema IP address
(NET+DLP0? ) (NET+DLP0! "192.168.206.010") Query Cinema IP address and response
Calibration Lens Mount and Lens System (PCB)
DESCRIPTION
Calibrating lens mount system at horizontal, vertical, zoom and focus lens to find home position, and the actual
motor travel range on each axis. Also doing motor backlash calculating for each motor.
SUBCODE
None
FBLL
FBLR
FRGL
FRGR
HBLL
HBLR
HRGL
4-16
DESCRIPTION OF USE
Run home position calibration on specified axis or at all axes.
Input range 0 - 5 0: Cancel calibration 1) Run calibration on hori-
zontal axis of lens mount system 2) Run calibration on vertical
axis of lens mount system 3) Run calibration on zoom Lens 4) Run
calibration on focus lens 5) Run calibration on all axes.
READ ONLY! Get the motor backlash on left-side of focus lens.
READ ONLY! Get the motor backlash on right-side of focus lens.
READ ONLY! Get the motor left-side travel range of focus lens.
READ ONLY! Get the motor right-side travel range of focus lens.
READ ONLY! Get the motor backlash on left-side of horizontal
axis.
READ ONLY! Get the motor backlash on right-side of horizontal
axis.
READ ONLY! Get the motor left-side travel range of horizontal
axis.
CP2000-M/MR Service Booklet
020-100220-02 Rev. 1 (07/08)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cp2000-mr

Table of Contents