Table 4.1 Function Codes
EXAMPLES:
(SST+ALRM?) returns (SST+ALRM!000 002 "101" "Prism temperature")
Where parameters are P1=index number, P2=error level, P3=value, P4=description.
Error level is 0=no errors or warnings, 1=warning, 2=error, 3=error and warning
Target Color Gamut (TCG)
DESCRIPTION
Set the Target Color Gamut file. This file describes desired output colorimetry from the projector. For this control
to function the Measured Color Gamut Data must be accurate.
SUBCODE
Cxxx
None
Temp
EXAMPLES:
(TCG+C108 "Altanis") Use file "Altanis" on channel 108
(TCG+C108? ) get target color file name on channel 108
(TCG?L) list all available entries of target color control
(TCG+TEMP "Altanis") Use file "Altanis" as DLP active file
3D Enable (TDC)
DESCRIPTION
Enable/Disable 3D on the specified channel. This controls the frame rate multiplication features that allow for
simulated three dimensional image projection.
SUBCODE
Cxxx
None
EXAMPLES:
(TDC+C108 1) Enable 3D on channel 108
(TDC+C108?) get 3D setting on channel 108
(TDC?) get current 3D status
Display Reference GPI (TDI)
DESCRIPTION
Setup Display Reference GPI for 3D control. This signal selects the input signal that will be used as a reference to
synchronize multiple projectors so that the gating technology so that the images can be targeted to the correct
eyes.
SUBCODE
Cxxx
None
CP2000-M/MR Service Booklet
020-100220-02 Rev. 1 (07/08)
DESCRIPTION OF USE
Replace xxx with the channel number. Valid Range is 101 - 164.
Select target color gamut for the current channel.
Select target color file as DLP active file, do not change channel
settings.
DESCRIPTION OF USE
Replace xxx with the channel number. Valid Range is 101 - 164.
Select 3D enable for the current channel.
DESCRIPTION OF USE
Replace xxx with the channel number. Valid Range is 101 - 164.
Select display GPI for the current channel.
Section 7: Serial Communications