Table 4.1 Function Codes
EXAMPLES:
(TOP?L) list all on Output Reference Polarity control
(TOP+C101 1) set Output Reference Polarity to 1 on channel 101
(TOP+C101? get Output Reference Polarity on channel 101
User ID login (UID)
DESCRIPTION
Log the username in with a password or query the current logged in level.
SUBCODE
None
None
EXAMPLES:
Request the log in level (UID?). Response is (UID! "username" xx) where xx is the user level
User levels are: status ( 1 ), Operator ( 2 ), Operator advanced ( 3 ), Advanced ( 4 ), Admin ( 5 ), Service ( 6 )
(UID) "username" "password") Login a user
(UID) Logout the current user, also happens automatically when a new user logs in
(UID?)(UID! "username" 01) Display the current logged in user and their access level
Zoom Lens Position Adjustment (ZOM)
DESCRIPTION
Adjust zoom lens to specific position.
SUBCODE
Cxxx
None
EXAMPLES:
(ZOM 500) Move zoom lens to position 500
CP2000-M/MR Service Booklet
020-100220-02 Rev. 1 (07/08)
DESCRIPTION OF USE
Log in user (UID "username" password").
None
DESCRIPTION OF USE
Replace xxx with the channel number. Valid Range is 101 - 164.
Moving zoom motor to a specified position.
Default data range -1050 to 1050, by using pre-calibration feature
it might be changed to be an actual value.
Section 7: Serial Communications