Christie CP2000-M Service Booklet page 88

Hide thumbs Also See for CP2000-M:
Table of Contents

Advertisement

Table 4.1 Function Codes
Focus Lens Position Adjustment (FCS)
DESCRIPTION
Adjust focus lens to specific position.
SUBCODE
None
EXAMPLES:
(FCS 500) Move focus lens to position 500
(FCS+C101 300) Set the focus position on Channel 101 to 300
Gamma Control (GAM)
DESCRIPTION
Gamma control, gamma file will be set when PCF in Use (PIU) is OFF. This control describes the gamma
response curve for the source signal.
SUBCODE
Cxxx
None
EXAMPLES:
(GAM+C108 "gamma 2.6") Use file "gamma 2.6" on channel 108
(GAM+C108?) get gamma file name on channel 108
(GAM?L) list all entries of gamma control
ILS Config (ILS)
DESCRIPTION
Enable/disable the Intelligent Lens System in specified channel.
SUBCODE
Cxxx
None
EXAMPLES:
(ILS+C101 1) Enable ILS at Channel 101
(ILS+C101 0) Disable ILS at channel 101
CP2000-M/MR Service Booklet
020-100220-02 Rev. 1 (07/08)
DESCRIPTION OF USE
Moving focus motor to a specified position. Default data range
1040 to 1040, by using pre-calibration feature it might be changed
to be an actual value.
DESCRIPTION OF USE
Replace xxx with the channel number. Valid Range is 101 - 164.
Select gamma for the current channel.
DESCRIPTION OF USE
Replace xxx with the channel number. Valid Range is 101 - 164.
Select ILS for current channel.
Section 7: Serial Communications
4-7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cp2000-mr