2.7.8 LOW VOLTAGE POWER SUPPLY (LVPS) - PHASE I

Follow this procedure if the LVPS module for your projector is identical to what is outlined in this
section.
(35 minutes)
1. Remove top lid. Refer to
2. Unlock and open the rear door using the low security key.
3. Remove exhaust panel skin. Refer to
4. Manually disconnect the 2 center channels (brown SW 1/blue SW 2) from the AC selector switch
(Figure 2-37).
F
IGURE
5. Remove the 3mm nut from the GRN terminal (Figure 2-38).
6. Unlock the high security access lock and remove the 6 screws securing the high security cover.
Lift the lid and slide out.
7. Use a #2 Phillips™ screwdriver to loosen the 2 thumbscrews on top of the cardcage.