Section 5: Parts and Module Replacement

2.6.6 UV FILTER

Handle the UV filter by its edges while wearing clean, lint free gloves.
The UV filter is secured to the end of the light tube. In the instance that a lamp explosion occurs the
UV filter will need to be replaced.
(60 minutes; includes 10 minute LampLOC™ alignment)
1. Open the lamp door frame skin.
2. Remove top lid. Refer to
3. Remove the lamp. Refer to
4. Remove the reflector assembly. Refer to
2-22.
5. Use a #1 Phillips™ to remove the top 2 screws and attached clamps (Figure 2-24, A).
6. Slowly loosen the 3rd screw until the glass can be removed
(Figure 2-24, B).
7. Reverse the above steps to reinstall. Ensure the filter is installed
with the arrow indicator on the edge of the filter pointing towards
the lamp (Figure 2-25).
8. Perform LampLOC™ adjustment. For details, refer to the
CP2000M-MR User Manual (020-100123-xx).
2-24
2.5.5 Top Lid, on page
2.5.14 Remove Lamp, on page
F
2-24 R
UV F
IGURE
EMOVE
CAUTION
2-10.
2-18.
2.6.4 Reflector Assembly (Including Heat Dump), on page
A
B
ILTER
Top Screws - Remove
Bottom Screw - Loosen
F
2-25 O
IGURE
RIENTATION