Parameter
MP number
iTNC MP number
CfgActivateKinem
Active machine kinematics;
A certain kinematic configuration can be activated with this entry.
kinemToActivate
204001
CfgChannelFile
Definition of the initialization files for this channel;
Specifies the paths of system cycles of the geometry calculation, for example.
The parameters are predefined by HEIDENHAIN and should not be changed.
geoChainInit
200401
geoIniProgram
200402
geoIniBlock
200403
geoIniCycle
200404
geoCycleEnd
200405
geoCancelCycle
200406
geoTCallCycPath
200407
January 2012
Function and input
Kinematics to be activated / Active kinematics
Define here the key name of the kinematic
configuration to be activated. You can also see
from this parameter which kinematics
configuration is currently active.
Format:
Selection menu
Input:
Key name of the kinematics model
from CfgKinComposModel
Path/name of the file for initializing the
geometry chain
Format:
String
Input:
Max. 260 characters
Path/name of the lead program for program
run
Format:
String
Input:
Max. 260 characters
Path/name of the lead program for MDI mode
Format:
String
Input:
Max. 260 characters
Path/name of the lead program for manual
cycles
Format:
String
Input:
Max. 260 characters
Path/name of the trailing program for
program end
Format:
String
Input:
Max. 260 characters
Path/name of the trailing program if program
aborts
Format:
String
Input:
Max. 260 characters
Path/name for the TOOL CALL cycle
Format:
String
Input:
Max. 260 characters
4.10 List of Machine Parameters
Reaction/
Page
Access
RUN
738
LEVEL3
RESET
LEVEL3
RESET
LEVEL3
RESET
LEVEL3
RESET
LEVEL3
RESET
LEVEL3
RESET
LEVEL3
RESET
LEVEL3
499