672
Constraints:
An axis that is not configured as "active", or an axis that was set to the
"deactivated axis" activation status (e.g. with Module 9226 or 9418), is
treated as if it were not present.
For an axis set to the "displayed axis" or "manually operated axis" activation
status the status information codes 2 and 8 are meaningless, and return the
value 0. The other status information codes return a value corresponding to
the configuration or activation status.
Call:
PS
B/W/D/K <>Axis>
Axis-specific: Index from CfgAxes/axisList
For all axes: –1
PS
B/W/D/K <>Status information>
See table above
CM
9038
PL
B/W/D
<>Information>
Axis-specific: Status information according to table
For all axes: Bit-encoded
(Bit 0 corresponds to logic axis 0, etc.)
Error recognition:
Marker
Value
NN_GenApiModule
0
Error
1
NN_GenApiModule
1
ErrorCode
2
Meaning
Information was read
Error code in NN_GenApiModuleErrorCode
Status information not available
Axis not found
HEIDENHAIN Technical Manual MANUALplus 620

Advertisement