Parameter
MP number
iTNC MP number
posEncoderDist
400005
MP331
posEncoderIncr
400006
MP332, MP3142
posEncoderRefDist
400007
MP334
genExtIntPolFactor
400017
MP340
January 2012
Function and input
Distance for number of signal periods from
MP_posEncoderIncr
Enter 360° for spindles.
For multiturn encoders with EnDat interface,
enter the distance traversed per encoder
revolution.
Format:
Numerical value
Input:
0.001 to 999 999 999 [mm] or [°]
Default:
5.000 [mm]
Number of signal periods for distance from
MP_posEncoderDist
Number of increments of external encoder. For
spindles, enter the line count of the encoder used.
For multiturn encoders with EnDat interface,
enter the increments per encoder revolution.
Format:
Numerical value
Input:
1 to 100 000 [incr]
Default:
2 048 [incr]
Nominal increment between two fixed
reference marks
Number of signal periods between the reference
marks. The attribute is only relevant for encoders
with distance-coded reference marks.
Format:
Numerical value
Input:
1 to 65 535 [incr]
Default:
1 000 [incr]
External interpolation for encoder signals
Only functional for the CC 61xx and CC 424
controller units.
Format:
Numerical value
Input:
0 to 99
0, 1: No external interpolation
4.10 List of Machine Parameters
Reaction/
Page
Access
RUN
653
LEVEL3
RUN
653
LEVEL3
RUN
653
LEVEL3
RUN
655
LEVEL3
521