772
MP_ultimatePosDiff
Synchronization monitoring – non-deletable emergency stop
message
Available from NCK software version: 597 110-04.
Format:
Numerical value
Input:
Maximum permissible offset [mm]
Default:
0
Access:
LEVEL3
Reaction:
RUN
MP_scalingFactor
Scaling factor for calculating the slave position
Available from NCK software version: 597 110-04.
Format:
Numerical value
Input:
Any values, even negative values (on modulo axes only ±1 is
can be entered)
Default:
1
Access:
LEVEL3
Reaction:
RUN
MP_accFilterTime
Time constant for filtering the acceleration curve
Available from NCK software version: 597 110-04.
Format:
Numerical value
Input:
0 to 200 [ms]
Default:
30
Access:
LEVEL3
Reaction:
RUN