Download Print this page

HEIDENHAIN MANUALplus 620 Technical Manual page 435

Hide thumbs Also See for MANUALplus 620:

Advertisement

Parameter
MP number
iTNC MP number
ProgramManager
Configuration of the program manager for file management.
CfgFileType
Assignment of the editor to a file type;
Depending on the file extension, a standard editor as well as further data required for controlling the
editing process are assigned.
[Key name of the file extension]
e.g.: H (HEIDENHAIN programs), I (ISO programs), CMA (table for axis-error compensation), etc.
unitOfMeasure
102901
standardEditor
102902
fileSize
102903
(optional parameter)
January 2012
Function and input
Unit of measure for length (metric/inch)
Position display, NC programs, tables etc.
Format:
Selection menu
Input:
UNIT_MM:
Input in mm
UNIT_INCH:
Input in inches
UNIT_MMINCH:
Input in mm or inches
UNIT_INDEPENDENT:
Input without unit of measure
Standard editor used for this file
Format:
Selection menu
Input:
TEXT EDITOR
PROGRAM EDITOR
TABLE EDITOR
HELP VIEWER
PATTERN EDITOR
File size above which the alternative editor is
used
Files larger than MP_fileSize are no longer
converted into binary format by the program
editor.
Format:
Numerical value
Input:
File size [KB]
4.10 List of Machine Parameters
Behavior
Page
Access
SW vers.
PLC/Pgm
1595
run is
locked
LEVEL3
PLC/Pgm
1595
run is
locked
LEVEL3
PLC/Pgm
1595
run is
locked
LEVEL3
435

Advertisement

loading