Download Print this page

HEIDENHAIN MANUALplus 620 Technical Manual page 806

Hide thumbs Also See for MANUALplus 620:

Advertisement

806
MP_moveAfterRef
Activate movement after finding the reference mark
Available from NCK software version: 597 110-02.
Format:
Selection menu
Selection:
on
Positioning after reference-mark traverse is active
off
No positioning after reference-mark traverse
Default:
off
Access:
LEVEL3
Reaction:
REF
MP_moveAfterRefType
Type of movement after finding the reference mark
Available from NCK software version: 597 110-02.
Format:
Selection menu
Selection:
absolute
Absolute positioning. This function is mainly intended for
positioning rotary tables. Please ensure that no collision occurs
as a result of this positioning. The software limit switches are
already active.
relative
Incremental positioning
HirthRasterPos
Approach next Hirth grid position in positive direction.
HirthRasterNeg
Approach next Hirth grid position in negative direction.
Default:
absolute
Access:
LEVEL3
Reaction:
REF
MP_moveAfterRefPos
Position for positioning after traversing the reference mark
Available from NCK software version: 597 110-01.
Format:
Numerical value
Input:
–100 000.000 000 000 to +100 000 [mm] or [°]
Default:
0
Access:
LEVEL3
Reaction:
REF
MP_moveAfterRefFeed
Feed rate for positioning after traversing the reference mark
Available from NCK software version: 597 110-01.
Format:
Numerical value
Input:
10.000 000 000 to 36 000 000 [mm/min] or [°/min]
Default:
6 000
Access:
LEVEL3
Reaction:
REF
HEIDENHAIN Technical Manual MANUALplus 620