Download Print this page

HEIDENHAIN MANUALplus 620 Technical Manual page 569

Hide thumbs Also See for MANUALplus 620:

Advertisement

Parameter
MP number
iTNC MP number
motFieldAdjustMove
401315
MP2254.x
(optional parameter)
motFieldAdjustInfo
401322
MP2252.x
(optional parameter)
motPhiRef
401316
MP2256.x
(optional parameter)
January 2012
Function and input
Feed-angle adjustment mode
Format:
Selection menu
Input:
mode 0:
Rough determination of the field angle during
operation
(soft key has no function)
Field angle is determined for a motor at
standstill. No plausibility tests. Use parameter
MP_motTypeOfFieldAdjust to specify the
method for rough determination of the field
angle.
mode 1:
Only on CC 422.
Precise determination of the field angle via soft
key. Use only for spindles or motors without
limit switches!
Do not use for hanging axes! Drive is moved
during field angle determination.
mode 2:
Only with CC 424, CC 61xx.
Precise determination of the field angle via soft
key. Drive is moved during field angle
determination.
Caution: No position monitoring (following error
or software limit switch)! Recommended for
horizontal axes or hanging axes with full weight
compensation.
mode 3:
Like mode 2. However, the drive does not have
to be enabled via the PLC.
Default:
mode 0
Field-angle determination (reserved)
Only for the CC 61xx.
Additional parameters for field-angle adjustment
with plausibility check.
Format:
Numerical value
Input:
Reserved
Default:
0
Field angle determined (is entered by the
MANUALplus 620 after it has been
determined)
Format:
Numerical value
Input:
Is entered by the MANUALplus 620
0: Field angle not yet determined
Default:
0
4.10 List of Machine Parameters
Reaction/
Page
Access
RUN
1062
LEVEL3
597 110-05
RUN
LEVEL3
RUN
1070
LEVEL3
569

Advertisement

loading