Download Print this page

HEIDENHAIN MANUALplus 620 Technical Manual page 562

Hide thumbs Also See for MANUALplus 620:

Advertisement

Parameter
MP number
iTNC MP number
ampAcFailSelection
401207
ampFactorI2t
401208
MP2304.x
(optional parameter)
562
Function and input
Signal for powerfail
Defines whether the powerfail in the control is
generated via the AC-fail and/or the powerfail
signal of the power module.
Format:
Selection menu
Input:
AC fail only generated:
Only AC-fail signal
Power fail and AC fail generated:
Powerfail and AC-fail signals
AC fail / power fail inactive:
AC fail and powerfail deactivated
Power fail only generated:
Only powerfail signal
Default:
Power fail only generated
2
Reference value for I
t monitoring of the
power module
Format:
Numerical value
Input:
0.000 000 000 to 1000
[· rated current of power module]
0: Monitoring is switched off
1: Rated current of power module
is
reference value
Default:
1
HEIDENHAIN Technical Manual MANUALplus 620
Reaction/
Page
Access
RUN
934
LEVEL3
RUN
970
LEVEL3

Advertisement

loading